smartd 데몬을 이용한 HDD Disk 상태 관리

smartd 데몬을 이용한 HDD Disk 상태 관리


작성자 : 서진우


smartd 데몬은 서버에 장착된 하드디스크의 상태를 사전에 감지하여 데이터 손실
위험을 예방하는 도구이다.


사용은 smartctl 이란 명령을 통해 가능하다.


기본적으로 디스크의 전반적인 상태를 확인하는 방법이다.


smartctl -a <device_name>




[root@alang03 ~]# smartctl -a /dev/sdc
smartctl version 5.38 [x86_64-redhat-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/


=== START OF INFORMATION SECTION ===
Device Model:     ST31000528AS
Serial Number:    9VPA5HSS
Firmware Version: CC46
User Capacity:    1,000,204,886,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Tue May 22 15:08:19 2012 KST
SMART support is: Available – device has SMART capability.
SMART support is: Enabled


=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.


General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
          was completed without error.
          Auto Offline Data Collection: Enabled.
Self-test execution status:      (  73) The previous self-test completed having
          a test element that failed and the test
          element that failed is not known.
Total time to complete Offline
data collection:     ( 609) seconds.
Offline data collection
capabilities:        (0x7b) SMART execute Offline immediate.
          Auto Offline data collection on/off support.
          Suspend Offline collection upon new
          command.
          Offline surface scan supported.
          Self-test supported.
          Conveyance Self-test supported.
          Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
          power-saving mode.
          Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
          General Purpose Logging supported.
Short self-test routine
recommended polling time:    (   1) minutes.
Extended self-test routinerecommended polling time:    ( 177) minutes.
Conveyance self-test routine
recommended polling time:    (   2) minutes.
SCT capabilities:          (0x103f) SCT Status supported.
          SCT Feature Control supported.
          SCT Data Table supported.


SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:


*********************************************************************************************


ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   115   099   006    Pre-fail  Always       –       86452274
  3 Spin_Up_Time            0x0003   095   095   000    Pre-fail  Always       –       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       –       94
  5 Reallocated_Sector_Ct   0x0033   026   026   036    Pre-fail  Always   FAILING_NOW 3064
  7 Seek_Error_Rate         0x000f   068   060   030    Pre-fail  Always       –       7295178
  9 Power_On_Hours          0x0032   086   086   000    Old_age   Always       –       12572
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       –       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       –       46
183 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       –       0
184 Unknown_Attribute       0x0032   100   100   099    Old_age   Always       –       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       –       0
188 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       –       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       –       0
190 Airflow_Temperature_Cel 0x0022   067   059   045    Old_age   Always       –       33 (Lifetime Min/Max 30/35)
194 Temperature_Celsius     0x0022   033   041   000    Old_age   Always       –       33 (0 7 0 0)
195 Hardware_ECC_Recovered  0x001a   047   009   000    Old_age   Always       –       86452274
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       –       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      –       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       –       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      –       64196876185982
241 Unknown_Attribute       0x0000   100   253   000    Old_age   Offline      –       2277322949
242 Unknown_Attribute       0x0000   100   253   000    Old_age   Offline      –       2355915261


***********************************************************************************************


SMART Error Log Version: 1
No Errors Logged


SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed: unknown failure    90%     12544         –
# 2  Extended offline    Completed: unknown failure    90%     12544         –
# 3  Extended offline    Completed: unknown failure    90%     12544         –


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

로그내용  중 ****** 로 표시된 구간의 정보를 통해 분석이 가능하다.


위 로그 상태를 보면 해당 디스크에 문제가 있다는 내용이다.


SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.


위 내용을 보면 자체 테스트에서 문제가 발생했으니, 데이터를 빨리 백업하란 얘기가 나온다.


만일 전체 내용 중 문제가 있는 부분만 확인하고자 한다면 아래 명령을 통해 가능하다.


[root@alang03 ~]# smartctl -q errorsonly -H -l selftest -l error /dev/sdc
———————————————————————————————-
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
Failed Attributes:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0033   026   026   036    Pre-fail  Always   FAILING_NOW 3064


Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed: unknown failure    90%     12544         –
# 2  Extended offline    Completed: unknown failure    90%     12544         –
# 3  Extended offline    Completed: unknown failure    90%     12544         –
————————————————————————————————


정상적인 상황에서는 위 명령을 실행하면 아무런 메세지가 나타나지 않는다.
만일 위 명령을 수행했을때 어떤 메세지가 나온다면, 한번쯤 해당 디스크 상태를 의심해 봐야 한다.


문제 로그 중 “Reallocated_Sector_Ct”의 내용은 섹터에 문제가 발생하여 스페어 영역으로 3064개의
섹터를 옮겼다는 의미이다. 이렇게 문제가 발생하면..점점 디스크 오류가 잦아지다가, 언젠가는
디스크 인식이 안되는등의 문제가 발생할 수 있다. 사전에 백업을 하거나 다른 디스크로 교체하는
것을 권장한다.


SMART 속성값의 의미에 대해 살펴보자..


Raw_Read_Error_Rate
디스크 표면으로 부터 데이터를 읽는 과정에서 문제가 있을때(주로 물리적인 충격으로 유발)
정상적인 디스크라면 0 값이겠지만..어느정도의 충격은 있을 수 있기 때문에 굳이 0이 아니더라도
크게 염려하진 않아도 될듯..


Sping_up_Time
플레터 회전에 제로 rpm 에서 최대 rpm에 도달하는 평균 시간


Start_Stop_Count
플레터가 회전하고 정지한 횟수


Reallocated_Sector_Ct
섹터에 문제가 생겨서 스페어 영역의 스페어 영역으로 섹터 이동
정상적인 경우 0


Seek_Error_Rate
탐색오류율, 정상적인 경우 0


Power_On_Hours
하드디스크에 전원이 인가된 시간


Spin_Retry_Count
최대 rpm에 도달하기 위해서 회전을 시도하는 횟수
정상적인 경우 0


Power_Cycle_Count
전원 on/off 횟수


Power-Off_retract_Count
헤드가 플레터에서 벗어나는 횟수


Load_Cycle_Count
헤드가 플레터위로 진입한 횟수


Temperature_Celsius
하드디스크 온도


Reallocated_Event_Count
스페어 영역으로 대체된 섹터로 부터 데이터를 읽어간 횟수


Current_Pending_Sector
불안전한 섹터로 스페어 영역 섹터로 remap을 준비중이러나 읽는 과정에 문제가 생긴 섹터
준 배드섹터로 정상적인 경우 0


Offline_Uncorrectable
읽기/쓰기 에 문제가 ㅂ생긴 섹터, 즉 디스크 표면이 손상됨. 배드섹터
정상적인 경우 0


UDMA_CRC_Error_Count
하드디스크 인터페이스를 통해 데이터 전송과정에 발생한 CRC 오류 횟수
정상적인 경우 0


Multi_Zone_Error_Rate
섹터에 쓰기과정에 발생한 에러가 검출된 횟수






서진우